1 Scope
This document specifies the determination of radium-226 (226Ra) activity concentration in non-saline water samples by extraction of its daughter
radon-222 (222Rn) and its measurement using liquid scintillation analysis.
The test method described in this document, using currently available scintillation
counters, has a detection limit of approximately 50 mBq·l−1. This method is not applicable to the measurement of other radium isotopes.