1   Scope

This part of ISO 10304 specifies a method for the determination of the dissolved anions chlorate, chloride, and chlorite in water with low contamination (e.g. drinking water, raw water or swimming pool water).
An appropriate pretreatment of the sample (e.g. dilution) and the use of a conductivity detector (CD), UV detector (UV) or amperometric detector (AD) make the working ranges given in table 1 feasible.
Table 1Working ranges of the analytical method
Anion
Working range
mg/l*
Detection
Chlorate 0,03 to 10 CD
Chloride 0,1 to 50 CD
Chlorite** 0,05 to 1 CD
  0,1 to 1 UV; λ =207 nm to 220 nm
  0,01 to 1 AD; 0,4 to 1,0 V
* The working range is restricted by the ion-exchange capacity of the columns. Dilute the sample in to the working range, if necessary.
** The minimum working range for chlorite of 0,05 mg/l was obtained using calibration checks, but the round robin trials (annex A, table A.4) showed that it is difficult to obtain this with sufficient accuracy. Thus great care shall be taken when working in the lower range of this method.