Water quality. Determination of dissolved anions by liquid chromatography of ions - Determination of chromate, iodide, sulfite, thiocyanate and thiosulfate

Water quality. Determination of dissolved anions by liquid chromatography of ions - Determination of chromate, iodide, sulfite, thiocyanate and thiosulfate

Regular price
£232.00
Sale price
£232.00
Regular price
£116.00
Sold out
Unit price
per 

1   Scope

This part of ISO 10304 specifies methods for the determination in aqueous solution of the dissolved anions
  • iodide, thiocyanate and thiosulfate (clause 4);
  • sulfite (clause 5);
  • chromate (clause 6).
An appropriate pretreatment of the sample (e.g. dilution) and the application of a conductivity detector (CD), UV detector (UV) or amperometric detector (AD) make the working ranges given in table 1 feasible.
Table 1Applicable working ranges
Anion Working range 1) Detector
1) The working range is restricted by the exchange capacity of the columns. Dilute the sample into the working range if necessary.
Chromate (CrO4), clause 6 0,05 mg/l to 50 mg/l UV (λ = 365 nm)
Iodide (I), clause 4 0,1 mg/l to 50 mg/l CD or UV (λ = 205 nm to 236 nm)
AD (approximately 0,7 V to 1,1 V)
Sulfite (SO3), clause 5 0,1 mg/l to 50 mg/l
0,5 mg/l to 50 mg/l
CD
UV (λ = 205 nm to 220 nm)
Thiocyanate (SCN), clause 4 0,1 mg/l to 50 mg/l CD or UV (λ = 205 nm to 220 nm)
AD (approximately 0,7 V to 1,1 V)
Thiosuifate (S2O3), clause 4 0,1 mg/l to 50 mg/l CD or UV (λ = 205 nm to 220 nm)
AD (approximately 0,7 V to 1,1 V)