1 Scope
This document describes the phased array ultrasonic testing (PAUT) of polyethylene
butt fusion (BF) joints, including pipe-to-pipe, pipe-to-fitting and fitting-to-fitting
joints, used for the conveyance of fluids. This document provides a test, whereby
the presence of imperfections such as voids, inclusions, lack of fusions, misalignment
and particulate contamination in the BF joints can be detected. The document is only
applicable to polyethylene pipes and fittings without a barrier to ultrasonic waves.
This document also provides requirements for procedure qualification and guidance
for personnel qualifications, which are essential for the application of this test
technique.
This document also covers the equipment, the preparation and performance of the test,
the indication assessment and the reporting for polyethylene BF joints.
Acceptance criteria are not covered in this document.