1 Scope
This Technical Report is an intercomparison supporting the development of IEC 61189‑5‑501 in relation to the SIR method. This document sets out to validate the introduction
of a new 200-µm gap SIR pattern, and was benched marked against existing SIR gap patterns
of 318 µm and 500 µm.