1. Scope*
NOTE 1— The machines with their pendulum-type hammers have been “standardized” in that they must comply with certain requirements, including a fixed height of hammer fall that results in a substantially fixed velocity of the hammer at the moment of impact. However, hammers of different initial energies (produced by varying their effective weights) are recommended for use with specimens of different impact resistance. Moreover, manufacturers of the equipment are permitted to use different lengths and constructions of pendulums with possible differences in pendulum rigidities resulting. (See Section 5.) Be aware that other differences in machine design may exist. The specimens are “standardized” in that they are required to have one fixed length, one fixed depth, and one particular design of milled notch. The width of the specimens is permitted to vary between limits.
NOTE 2— Results generated using pendulums that utilize a load cell to record the impact force and thus impact energy, may not be equivalent to results that are generated using manually or digitally encoded testers that measure the energy remaining in the pendulum after impact.
NOTE 3— The notch in the Izod specimen serves to concentrate the stress, minimize plastic deformation, and direct the fracture to the part of the specimen behind the notch. Scatter in energy-to-break is thus reduced. However, because of differences in the elastic and viscoelastic properties of plastics, response to a given notch varies among materials. A measure of a plastic’s “notch sensitivity” may be obtained with Test Method D by comparing the energies to break specimens having different radii at the base of the notch.
NOTE 4— Caution must be exercised in interpreting the results of these standard test methods. The following testing parameters may affect test results significantly:
-
Method of fabrication, including but not limited to processing
-
technology, molding conditions, mold design, and thermal
-
treatments;
-
Method of notching;
-
Speed of notching tool;
-
Design of notching apparatus;
-
Quality of the notch;
-
Time between notching and test;
-
Test specimen thickness,
-
Test specimen width under notch, and
-
Environmental conditioning.