What is BS EN 55016-1-1 - Specification for radio disturbance and immunity measuring apparatus and methods about?  

BS EN 55016 is a series on specifications for radio disturbance and immunity measuring apparatus and methods. radio disturbance occurs when in the radio frequency spectrum, is a disturbance generated by an external source that affects an electrical circuit by electromagnetic interference, electrostatic coupling, or conduction. BS EN 55016-1-1 specifies the characteristics and performance of equipment for the measurement of radio disturbance in the frequency range 9 kHz to 18 GHz. In addition, requirements are provided for specialized equipment for discontinuous disturbance measurements.  

The specifications in BS EN 55016-1-1 apply to EMI receivers and spectrum analyzers. The term “measuring receiver” used in this standard refers to both EMI receivers and spectrum analyzers.  

Who is BS EN 55016-1-1 - Specification for radio disturbance and immunity measuring apparatus and methods for? 

BS EN 55016-1-1 on the specification for radio disturbance and immunity measuring apparatus and methods is useful for: 

  • Telecommunication component manufacturers 
  • Telecommunication equipment manufacturers 
  • Design engineers 
  • Quality control personnel 

Why should you use BS EN 55016-1-1 - Specification for radio disturbance and immunity measuring apparatus and methods 

The disturbance may degrade the performance of the circuit or even stop it from functioning. In the case of a data path, these effects can range from an increase in error rate to a total loss of the data. The receiver specification depends on the frequency of operation. There is one receiver specification covering the frequency range 9 kHz to 150 kHz (Band A), one covering 150 kHz to 30 MHz (Band B), one covering 30 MHz to 300 MHz (Band C), and one covering 300 MHz to 1 000 MHz (Band D). Fundamental characteristics of a quasi-peak measuring instrument are provided in BS EN 55016-1-1. 

Spectrum analyzers and FFT-based measuring instruments that meet the requirements of BS EN 55016-1-1 can be used for compliance measurements. For emission measurements, FFT-based measuring instruments shall sample and evaluate the signal continuously during the measurement time. Using BS EN 55016-1-1 you can specify the characteristics and performance of equipment for the measurement of radio disturbance in the frequency range 9 kHz to 18 GHz.