1 Scope
This standard specifies the constructional and performance characteristics, safety
specifications and rational use of energy, relevant test methods and marking of boiling
burners burning liquefied petroleum gas and designed to heat up vessels containing liquids
or food, or a heating plate. They are referred to in the body of the text as `appliances'.
This standard covers appliances, generally floor standing, fitted with one or several
burners with a total heat input not exceeding 14 kW, designed to be used outdoors and operating with the gases indicated
in 4.1 according to the categories indicated in 4.2.
Appliances supplied with third family gas at pressures greater than those defined
in 4.2 are outside the field of application of this standard.
Appliances covered by this standard are not connected to a flue for the products of
combustion and are not connected to the mains electrical supply.
Appliances with a nominal heat input below 1,16 kW and appliances which are not designed to receive the test vessel described
in 7.1.4 in any of their configurations are not subject to any requirement concerning the
rational use of energy.
This standard applies only to type testing.