1 Scope
This part of ISO 17827 specifies a method for the determination of the size distribution of particulate
biofuels by the vibrating screen method. The method described is meant for particulate
biofuels only, namely, materials that either have been reduced in size, such as most
wood fuels, or are physically in a particulate form. This part of ISO 17827 applies to particulate uncompressed fuels with a nominal top size of 3,15 mm and
below (e.g. sawdust).