1 Scope
-
— has a gas heat input not exceeding 70 kW; and
-
— has a hot water storage capacity not exceeding 500 l; and
-
— is equipped with at least one solar collector; and
-
— is, with regard to the solar hydraulic circuit, considered as a forced circulation system (definition according to EN ISO 9488:1999).
NOTE In principle, the energy consumption of thermo-siphon solar preheat systems and integral collector storage preheat systems can also be assessed on the basis of this standard. One appropriate procedure for that purpose is to calculate the temperature level of the domestic hot water withdrawn from the thermal solar system for the reference conditions defined in this standard by using the numerical system model and the thermal solar system performance parameters according to ISO 9459‑5. Based on the temperature level of the hot water withdrawn from the store the energy consumption of the gas appliance should be determined. This determination can either be done by means of calculations or by performing a test according to EN 13203‑2 and using instead of the cold water inlet temperature the hot water temperature withdrawn from the store.
-
— of the solar collector(s), which should comply with EN 12975‑1 and EN 12975‑2; and
-
— thermal solar systems and components, which should comply with EN 12976‑1 and EN 12976‑2.