1   Scope

This European Standard specifies:
  • the dimensional, leaktightness, mechanical and hydraulic characteristics with which shower hoses shall comply;
  • the procedures for testing these characteristics.
This European Standard applies to shower hoses of any material used for ablutionary purposes and intended for equipping and supplementing sanitary tapware for baths and showers.
This European Standard applies to shower hoses connected downstream of the obturator of the tapware.
Hoses which are an integral part of sanitary tapware (sink and wash basin mixing valves) or hoses intended to connect sanitary tapware to the water supplies are not covered by this European Standard.
Details of pressures and temperatures are given in Table 1.
Table 1Conditions of use/Classifications
Water Supply system
Operating range of shower hoses
Flow rates
Limits
Recommended
See Table 3
Type 1
see Figure 1
Dynamic Pressure
0,05 MPa to 0,5 MPa
0,5 bar to 5 bar
Dynamic Pressure
(0,1 to 0,3) MPa
(1,0 to 3,0) bar
Min. 0,42 l/s (25,2 l/min)
at 0,3 + 0,02 MPa (3 + 0,2 bar)
  Dynamic Pressure Dynamic Pressure Class E
Type 2
(0,01 to 0,2) MPa
(0,1 to 2) bar
(0,02 to 0,10) MPa
(0,2 to 1,0) bar
0,06 l/s < Q < 0,18 l/s (3,6 l/min < Q < 10,8 l/min.)
at 0,01 MPa (0,1 bar)
see Figure 2     Class H
      0,18 l/s ≤ Q (10,8 l/min ≤ Q) at 0,01 MPa (0,1 bar)
Temperature T ≤ 70°C T ≤ 42°C  
Figure 1Type 1 Water supply system with a pressure range of (0,05 – 1,0) MPa (0,5 - 10) bar
fig_1
1 Cold water
2 Hot Water
3 Mains supply pipe (Supply pressures up to 10 bar)
4 Water heate
Figure 2Type 2 Water supply system - with a pressure range of (0,01 - 1.0) MPa, (0,1 - 10) bar. A vented domestic hot water and cold water supply system incorporating gravity hot water, mains cold water and alternative gravity cold water supply to sanitary appliances
fig_2
1 cold water storage cistern (cover omitted for clarity)
2 warning pipe
3 vent pipe
4 hot water cylinder
5 alternative cistern fed cold supply to sanitary appliances
6 to boiler
7 mains supply pipe (Supply pressures up to 10 bar)