Sanitary tapware. Low pressure thermostatic mixing valves. General technical specification

Sanitary tapware. Low pressure thermostatic mixing valves. General technical specification

Regular price
£322.00
Sale price
£322.00
Regular price
£161.00
Sold out
Unit price
per 

1   Scope

This European Standard specifies general construction, performance and material requirements for PN 10thermostatic mixing valves (TMV) and includes test methods for the verification of mixed water temperature performance at the point of use below 45 °C. This does not exclude the selection of higher temperatures where available. When these devices are used to provide anti-scald protection for children, elderly and disabled persons the mixed water temperature needs to be set at a suitable bathing temperature (body temperature – 38 °C) as children are at risk to scalding at lower temperatures than adults. This does not obviate the need for supervision of young children during bathing.
It applies to valves intended for use on sanitary appliances in kitchens, washrooms (incl. all rooms with sanitary tapware, e.g. toilet and cloakrooms) and bathrooms operating under the conditions specified in Table 1.
This standard allows TMVs to supply a single outlet or a small number of outlets in a “domestic” application (e.g. one valve, controlling a shower, bath, basin and/or, bidet), excluding valves specifically designed for supplying a large number of outlets (i.e. for institutional use).
The tests described are type tests (laboratory tests) and not quality control tests carried out during manufacture.
Table 1Conditions of use
Supply Operating range a
Pressure limits recommended
Static ≤ 1 MPa [≤10 bar]
Dynamic ≥ 0,01 MPa [≥0,1 bar] (0,02 to 0,1) MPa [(0,2 to 1,0) bar]
Temperature    
Hot ≤ 90 °C (55 to 65) °C
Cold ≤ 25 °C (5 to 20) °C
a For low pressure thermostatic mixing valves complying with this table there are no acoustical requirements. Low pressure thermostatic mixing valves complying with this standard may also be used with inlet supply pressures in the range from 0,1 MPa to 0,2 MPa (1,0 bar to 2,0 bar) on condition that acoustical performance is not a requirement of the installation.

NOTE Low pressure thermostatic mixing valves are designed to provide sufficient mechanical strength for operation at 1 MPa (10 bar) static pressure.