1 Scope
This European Standard specifies general construction, performance and material requirements
for PN 10thermostatic mixing valves (TMV) and includes test methods for the verification of mixed water temperature performance
at the point of use below 45 °C. This does not exclude the selection of higher temperatures
where available. When these devices are used to provide anti-scald protection for
children, elderly and disabled persons the mixed water temperature needs to be set
at a suitable bathing temperature (body temperature – 38 °C) as children are at risk
to scalding at lower temperatures than adults. This does not obviate the need for
supervision of young children during bathing.
It applies to valves intended for use on sanitary appliances in kitchens, washrooms
(incl. all rooms with sanitary tapware, e.g. toilet and cloakrooms) and bathrooms
operating under the conditions specified in Table 1.
This standard allows TMVs to supply a single outlet or a small number of outlets in a “domestic” application
(e.g. one valve, controlling a shower, bath, basin and/or, bidet), excluding valves
specifically designed for supplying a large number of outlets (i.e. for institutional
use).
The tests described are type tests (laboratory tests) and not quality control tests
carried out during manufacture.
Table 1
—
Conditions of use
| Supply | Operating range a | |
|---|---|---|
| Pressure | limits | recommended |
| Static | ≤ 1 MPa [≤10 bar] | |
| Dynamic | ≥ 0,01 MPa [≥0,1 bar] | (0,02 to 0,1) MPa [(0,2 to 1,0) bar] |
| Temperature | ||
| Hot | ≤ 90 °C | (55 to 65) °C |
| Cold | ≤ 25 °C | (5 to 20) °C |
a For low pressure thermostatic mixing valves complying with this table there are no acoustical requirements. Low pressure thermostatic mixing valves complying with this standard may also be used with inlet supply pressures in the
range from 0,1 MPa to 0,2 MPa (1,0 bar to 2,0 bar) on condition that acoustical performance
is not a requirement of the installation.
NOTE Low pressure thermostatic mixing valves are designed to provide sufficient mechanical strength for operation at 1 MPa (10 bar) static pressure.