What is BS EN 61010-031- Hand-held probe assemblies about?
BS EN 61010 discusses safety requirements for electrical equipment for measurement, control, and laboratory use. BS EN 61010-031 belongs to BS EN 61010 multi-series and specifies safety requirements for hand-held and hand-manipulated probe assemblies of the types described below, and their related accessories.
These probe assemblies are for direct electrical connection between a part and electrical test and measurement equipment. They may be fixed to the equipment or be detachable accessories for the equipment.
Note 1: BS EN 61010-031 does not apply to current sensors within the scope of IEC 61010-2-032 (Handheld and hand-manipulated current sensors), but may apply to their input measuring circuit leads and accessories.
Note 2: Additional requirements for probe assemblies that are designed to be powered from a low voltage mains supply, or include other features not specifically addressed in this standard are in other parts of IEC 61010.
Who is BS EN 61010-031 - Hand-held probe assemblies for?
BS EN 61010-031 on hand-held probe assemblies is useful for:
- Probe assemblies manufactures
- Testing Laboratories
- Quality control personnel
Why should you use BS EN 61010-031- Hand-held probe assemblies for electrical measurement?
Probe technology comes in multiple standard and custom-engineered configurations to meet any combination of requirements including sensing element type, temperature range, thermal response time, vibration resistance, and mounting method.
BS EN 61010-031 helps you to ensure that hazards to the operator of hand-held probe assemblies and the surrounding area are reduced to a tolerable level. BS EN 61010-031 provides you with requirements for the protection against types of hazards.
BS EN 61010-031 also provides you with the methods of verifying that the probe assembly meets the requirements of BS EN 61010-031, through inspection, type test, and routine tests. BS EN 61010-031 helps you to ensure the safety of hand-held probe assemblies.
What’s changed since the last update?
BS EN 61010-031:2015 supersedes BS EN 61010-031:2002+A1:2008 which is withdrawn. BS EN 61010-031:2015 includes some technical changes with respect to BS EN 61010-031:2002+A1:2008. These include:
- Voltages above the levels of 30 V r.m.s., 42,4 V peak, or 60 V d.c. are deemed to be HAZARDOUS LIVE instead of 33 V r.m.s., 46,7 V peak, or 70 V d.c.
- Servicing is now included within the scope
- Extended environmental conditions are included within the scope.
- New terms have been defined
- Tests for REASONABLY FORESEEABLE MISUSE have been added, for fuses