Safety requirements for electrical equipment for measurement, control and laboratory use - Particular requirements for laboratory equipment for the heating of materials

Safety requirements for electrical equipment for measurement, control and laboratory use - Particular requirements for laboratory equipment for the heating of materials

Regular price
£272.00
Sale price
£272.00
Regular price
£136.00
Sold out
Unit price
per 

What is IEC 61010-2-010 about? 

IEC 61010-2-010 is the second sub-part of the tenth part of multiple series is the clause of Part 1 is applicable except as follows:  

Equipment included in the scope 

  • Replacement: 

Replace the second paragraph with the following: 

IEC 61010-2-010 specifies particular safety requirements for the following types a) to c) of electrical equipment and their accessories, wherever they are intended to be used, wherever the heating of materials is one of the functions of the equipment. 

  • Addition: 

It is possible that all or part of the equipment falls within the scope of one or more other 

Part 2 standards of IEC 61010 as well as within the scope of IEC 61010-2-010. In that case, the requirements of those other Part 2 standards will also apply. In particular, if the equipment is intended to be used for in vitro diagnostic (IVD) purposes, the requirements of IEC 610102101 will also apply. However, when the equipment incorporates a refrigerating system and a heating function where the combination of the two introduces additional or more severe hazards than if treated separately, then it is possible that IEC 61010-2-012 is applicable instead of this Part 2-010. 

Note: See further information in the flow chart (Figure 102) for the selection process and the guidance in the Introduction. 

Equipment excluded from the scope 

  • Addition: 
  • Equipment for the heating and ventilation of laboratories 
  • Sterilizing equipment 
  • Heating and/or cooling equipment which the operator is intended to enter, and which is large enough for the operator to remain inside with the door or doors closed. 

Who is IEC 61010-2-010 for?  

IEC 61010-2-010 on laboratory equipment for the heating of materials is useful for: 

  • Clinical testing laboratory 
  • Manufacturer of equipment for the heating of materials 
  • Maintenance and service provider of equipment 

Why should you use this IEC 61010-2-010 

When the equipment includes only a material heating system, and no refrigerating system or other environmental factors adapt IEC 61010-2-010 to perform the test. 

If a hazard is caused by over-filling or under-filling with a liquid “HEAT TRANSFER MEDIUM” IEC 61010-2-010 helps you to perform a test of the heating device. Also, make sure before testing the equipment is empty, partially filled, or overfilled, whichever is least favourable. 

IEC 61010-2-010 provides safety requirements for electrical equipment and its accessories. This will help you to protect against electric shock, mechanical hazards, the spread of fire, fluids and solid foreign objects, radiation (including laser sources, and sonic and ultrasonic pressure) liberated gases and substances (explosion and implosion). 

What’s changed since the last update? 

BS EN IEC 61010-2-010:2020 supersedes BS EN 610102010:2014, which is withdrawn. 

BS EN IEC 61010-2-010:2020 includes the following significant technical changes with respect to the BS EN 610102010:2014: 

  • Alignment with changes introduced by Amendment 1 of IEC 61010-1:2010 
  • Alignment with IEC 61010-2-011 and IEC 61010-2-012 
  • New matching Introduction clarifying which standard(s) to use 
  • New 5.4.101 instructions for flammable liquid heat transfer medium 
  • Subclause 9.5 on flammable liquids replaced with text from IEC 61010-2-012 
  • Subclause 5.2.101 deleted 
  • Requirements in 10.101 b) and c) clarified