1 Scope
This technical specification deals with the steady-state operation of cage induction
motors within the scope of IEC 60034‑12, when fed from converters. It covers the operation over the whole speed setting range,
but does not deal with starting or transient phenomena.
Only indirect type converters are dealt with. This type comprises converters with
impressed direct current in the intermediate circuit (current source converters) and
converters with impressed d.c. voltage (voltage source converters), either of the
block type or the pulse controlled type, without restriction on pulse number, pulse
width or switching frequency. For the purposes of this technical specification, a
converter may include any type of electronic switching device, for example transistors
(bipolar or MOSfet), IGBTs, thyristors, GTO-thyristors, etc. with analog or digital
control electronics.