1 Scope
This document specifies the laboratory test procedure for determining the clamping
force exerted by the fastening system on the foot of the rail by measuring the force
to separate the rail foot from its immediate support. When required, the procedure
is also used to determine the uplift stiffness of the fastening system.
It is applicable to systems with and without baseplates on all types of sleepers,
bearers or elements of ballastless track. The test does not determine the security
of the fastening components fixed into the sleeper or other fastening system support.
This test procedure applies to a complete fastening assembly. It is not applicable
to fastening systems for embedded rail or other fastening systems which do not act
on the foot of the rail.