1 Scope
This part of IEC 61169, which is a sectional specification (SS), provides information and rules for the
preparation of detail specifications (DS) for RF coaxial connectors with snap-on coupling,
typically for use in 50 Ω cable networks (MMCX).
It prescribes mating face dimensions for general purpose connectors – grade 2, dimensional
details of standard test connectors-grade 0, gauging information and tests selected
from IEC 61169‑1, applicable to all detail specifications relating to series MMCX RF connectors.
This specification indicates recommended performance characteristics to be considered
when writing a detail specification and it covers test schedules and inspection requirements
for assessment levels M and H.
The MMCX miniature snap-on coupling structure series R.F. coaxial connector with the
characteristic of normative impedance 50 Ω are used with various kinds of R.F cables
and strips. The operating frequency limit is up to 6 GHz.
NOTE Metric dimension are original dimensions. All undimensioned pictorial configurations are for reference purpose only.