1 Scope
This part of IEC 60966 is a sectional specification that relates to flexible coaxial cable assemblies operating
in the transverse electromagnetic mode (TEM). It establishes uniform requirements
for testing the electrical, mechanical and climatic properties of flexible cable assemblies
composed of flexible coaxial cables and coaxial connectors.
NOTE 1 For the purposes of this sectional specification, a cable assembly is always regarded as an integral unit. All specifications apply to the finished assembly and not to individual and non-assembled parts thereof.
NOTE 2 This sectional specification should be supplemented with detail specifications giving additional details as required by the particular application. This application will not necessarily require all tests.