1 Scope
This part of the IEC 62647 series defines for circuit card assemblies (CCA):
-
– a default method for those companies that require a pre-defined approach, and
-
– a protocol for those companies that wish to develop their own test methods.
The intent of this document is not to prescribe a certain method, but to aid avionics/defence
suppliers in satisfying the reliability and/or performance requirements of IEC/TS 62647‑1 as well as support the expectations in IEC/TS 62647‑21.
The default method (see Clause 5) is intended for use by electronic equipment manufacturers, repair facilities, or
programs that, for a variety of reasons, may be unable to develop methods specific
to their own products and applications. It should be used when little or no other
information is available to define, conduct, and interpret results from reliability,
qualification, or other tests for electronic equipment containing lead-free (Pb-free)
solder. The default method is intended to be conservative, i.e., it is biased toward
minimizing the risk to users of ADHP electronic equipment.
The protocol (see Clause 6) is intended for use by manufacturers or repair facilities that have the necessary
resources to design and conduct reliability, qualification, or process development
tests that are specific to their products, their operating conditions, and their applications.
Users of the protocol will have the necessary knowledge, experience, and data to customize
their own methods for designing, conducting, and interpreting results from the data.
Key to developing a protocol is a firm understanding of all material properties for
the lead-free (Pb-free) material in question as well as knowledge of package- and
board-level attributes as described in 5.3.2. As an example, research has shown that the mechanisms for creep can be different
between tin-lead and tin-silver-copper (SAC) solders. Understanding these mechanisms
is key to determining critical test parameters such as dwell time for thermal cycling.
The protocol portion of this document provides guidance on performing sufficient characterization
of new materials in order to accurately define test parameters.
Use of the protocol is encouraged, since it is likely to yield more accurate results,
and to be less expensive than the default method. The IEC/TS 62647‑22 provides a comprehensive overview of those technical considerations necessary in
implementing a test protocol.
This specification addresses the evaluation of failure mechanisms, through performance
testing, expected in electronic products containing lead-free (Pb-free) solder. One
failure mode, fatigue-failure through the solder-joint, is considered a primary failure
mode in ADHP electronics and can be understood in terms of physics of failure and
life-projections. Understanding all of the potential failure modes caused by lead-free
(Pb-free) solder of ADHP electronics is a critical element in defining early field-failures/reliability
issues. Grouping of different failure modes may result in incorrect and/or misleading
test conclusions. Failure analysis efforts should be conducted to insure that individual
failure modes are identified, thus enabling the correct application of reliability
assessments and life-projection efforts.
When properly used, the methods or protocol defined in this specification can be used
along with the processes documented in compliance to the IPC-SM-785, to satisfy, at
least in part, the reliability requirements of the IPC-SM-785 and JESD22-B110A.
Any portion of this document can be used to develop a lead-free (Pb-free) assembly
test program, i.e., this document is tailorable and provides room for flexibility.
For those situations in which results are used for reliability, verification, or qualification,
stakeholder concurrence needs to be sought and documented so that expectations are
understood and addressed.
This specification may be used for products in all stages of the transition to lead-free
(Pb-free) solder, including:
-
• products that have been designed and qualified with traditional tin-lead electronic components, materials, and assembly processes, and are being re-qualified with use of lead-free (Pb-free) components;
-
• products with tin-lead designs transitioning to lead-free (Pb-free) solder; and
-
• products newly-designed with lead-free (Pb-free) solder.
For programs that were designed with tin-lead solder, and are currently not using
any lead-free (Pb-free) solder, the traditional methods may be used. It is important,
however, for those programs to have processes in place to maintain the tin-lead configuration
including those outsourced or manufactured by subcontractors.
With respect to products as mentioned above, the methods presented in this document
are intended to be applied at the level of assembly at which soldering occurs, i.e.,
circuit card assembly (CCA) level.
This document may be used by other high-performance and high-reliability industries,
at their discretion.