1 Scope
This part of IEC 62804 defines apparatus and procedures to test and evaluate the durability of photovoltaic
(PV) modules to power loss by the effects of high voltage stress in a damp heat environment,
referred to as potential-induced degradation (PID). This document defines a test method
that compares the coulomb transfer between the active cell circuit and ground through
the module packaging under voltage stress during accelerated stress testing with the
coulomb transfer during outdoor testing to determine an acceleration factor for the
PID. It is designed for thin-film PV modules and modules containing moisture sensitive
films protected by vapour barrier packaging, principally with one or two glass surfaces.
This document tests for the degradation mechanisms involving mobile ions influencing
the electric field over the semiconductor absorber layer or electronically interacting
with the films such that module power is affected. This document does not specifically
test for electrochemical corrosion or delamination associated with application of
system voltage. This document does not contain pass or fail criteria and it is not
intended for design qualification.
The procedures contained herein, with testing in chamber in combination with in the
field or testing in the field alone are intended for use when it is desired to quantify
the acceleration provided by the applied stress levels over regular use conditions
in the natural environment using coulombs transferred between the module and ground
as the index for damage incurred by PID. The procedures for quantifying the acceleration
are not recommended when coulombs transferred are not an indicator of damage by PID
to the module. The procedures are not directly applicable when moisture ingress into
the module laminate occurs affecting PID rate, and to the extent that there is power
recovery when the factor of system voltage bias is removed after correctly applying
the procedures herein, within the period of testing.
The protocols given herein give results according to the chamber stress levels applied
and the module grounding configuration used in the test. Because the stress method
of testing in an environmental chamber employs a non-condensing humidity level to
serve as a conductive pathway to electrical ground, it frequently applies relatively
less stress toward the centre of the module face. Also, the method can evaluate the
effectiveness of some construction methods to mitigate PID; for example, the use of
rear rail mounts, edge clips, and insulating frames. The test, however, does not include
all the factors existing in the natural environment that can affect the PID rate.
The actual durability of modules to system voltage stress depends on the actual environmental
conditions under which they are operated.