1 Scope and object
Photovoltaic (PV) modules are electrical devices intended for continuous outdoor exposure
during their lifetime. Highly corrosive wet atmospheres, such as in the environment
of stables of agricultural companies, could eventually degrade some of the PV module
components (corrosion of metallic parts, deterioration of the properties of some non-metallic
materials – such as protective coatings and plastics – by assimilation of ammonia)
causing permanent damages that could impair their functioning and safe operation.
This standard describes test sequences useful to determine the resistance of PV modules
to ammonia (NH3). All tests included in the sequences, except the bypass diode functionality test,
are fully described in IEC 61215, IEC 61646 and IEC 61730‑2. They are combined in this standard to provide means to evaluate possible faults
caused in PV modules when operating under wet atmospheres having high concentration
of dissolved ammonia (NH3).
This standard applies to flat plate PV modules. The structure of this standard follows
closely IEC 61701.