1 Scope
This part of IEC 62037 defines the impact test on coaxial connectors to evaluate their robustness against
weak connections and particles inside the connector, as independently as possible
from the effects of cable PIM (passive intermodulation).
For other connectors (e.g. panel mounted connectors), the cable can be replaced by
an adequate transmission-line (e.g. airline, stripline). In order to evaluate the
effects of mechanical stresses on the connectors, a series of impacts is applied to
the connectors while measuring the PIM.