Optical amplifiers. Test methods - Power and gain parameters - Electrical spectrum analyzer method

Optical amplifiers. Test methods - Power and gain parameters - Electrical spectrum analyzer method

Regular price
£166.00
Sale price
£166.00
Regular price
£83.00
Sold out
Unit price
per 

1 Scope

This part of IEC 61290 applies to all commercially available optical amplifiers (OAs) and optically amplified sub-systems. It applies to OAs using optically pumped fibres (OFAs based on either rare-earth doped fibres or on the Raman effect), semiconductors (SOAs), and waveguides (POWAs).

NOTE    The applicability of the test methods described in the present standard to distributed Raman amplifiers is for further study.

The object of this standard is to establish uniform requirements for accurate and reliable measurements, by means of the electrical spectrum analyzer test method, of the following OA parameters, as defined in Clause 3 of IEC 61291‑1:

  1. nominal output signal power

  2. gain;

  3. reverse gain;

  4. maximum gain;

  5. polarization-dependent gain;

  6. large-signal output stability;

  7. saturation output power;

  8. maximum input signal power;

  9. maximum output signal power;

  10. input power range;

  11. output power range;

  12. maximum total output power.

In addition this test method provides a means for measuring the following parameters:

  • maximum gain wavelength;

  • gain wavelength band.

NOTE    All numerical values followed by (‡) are suggested values for which the measurement is assured. Other values may be acceptable, but should be verified.

The object of this standard is specifically directed to single-channel amplifiers. For multichannel amplifiers, one should refer to the IEC 61290‑10 series1.