1 Scope
This standard specifies calculations for the dimensioning of Kachelgrundöfen/Putzgrundöfen
(tiled/mortared stoves) based upon the required nominal heat output of the stove as declared by the producer. The Kachelgrundöfen/Putzgrundöfen (tiled/mortared
stoves) are of individual one-off construction design. The standard can be used for
log wood fired Kachelöfen (tile stoves) that burn one fuel load per storage period
with a maximum load between 10 kg and 40 kg and a storage period (nominal heating time) between 8 h and
24 h.
This standard is valid for Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) equipped
with fireclay as interior material, with an apparent density between 1,750 kg/m3 and 2,200 kg/m3, a degree of porosity from 18 % up to 33 % by volume and a heat conductivity from
0,65 W/mK up to 0,90 W/mK (temperature range 20 °C to 400 °C).
This standard is valid for Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) with
sidewise combustion air supply of the combustion chamber and an inflow speed from
2 m/s to 4 m/s, whereas the height of the lowest opening is at least 5 cm above the
bottom of the combustion chamber.
This standard is not valid for combinations with water heat exchangers for central
heating or other heat absorbing elements like glass plates greater than 1/6 of the
combustion chamber surface, open water tanks, etc. It is also not valid for combinations with heating/fireplace
elements according to EN 13229. Furthermore this standard is not valid for mass-produced prefabricated or partly
prefabricated slow heat release appliances according to EN 15250.
NOTE Although for the purposes of this standard these calculations are applicable only to the requirements of this standard, the same calculations can be used for other purposes, e.g. to verify emission levels and energy efficiency in case of burning log wood or wood briquettes according to the producer’s manual.