1 Scope
1.1 General
-
— malicious modifications affecting system integrity;
-
— malicious interference with information, data or resources that could compromise the delivery of or performance of the required I&C programmable digital functions;
-
— malicious interference with information, data or resources that could compromise operator displays or lead to loss of management of I&C programmable digital systems;
-
— malicious changes to hardware, firmware or software at the programmable logic controller (PLC) level.
-
— non-malevolent actions and events such as accidental failures, human errors (except those impacting the performance of cybersecurity controls) and natural events. In particular, good practices for managing applications and data, including back-up and restoration related to accidental failure, are out of scope;
NOTE 1 Although such aspects are often covered by security programme in other normative contexts (e.g., in the ISO/IEC 27000 series or in the IEC 62443 series), this document is only focused on the protection against malicious acts by digital means (cyberattacks) on I&C programmable digital systems. The main reason is that in the nuclear generation domain, other standards and practices already cover accidental failures, unintentional human errors, natural events, etc. The focus of IEC 62645 is made to provide the maximum consistency and the minimum overlap with these other nuclear standards and practices.
-
— site physical security, room access control and site security surveillance systems. These systems, while not specifically addressed in this document, are to be covered by plant operating procedures and programmes;
NOTE 2 This exclusion does not deny that cybersecurity has clear dependencies on the security of the physical environment (e.g., physical protection, power delivery systems, heating/ventilation/air-conditioning systems (HVAC), etc.).
-
— the aspect of confidentiality of information about I&C digital programmable systems is out of the scope of this document (see 5.4.3.2.3).