1 Scope
This document establishes the requirements for instrumentation necessary to detect leakage from reactor coolant systems of all types of light water and heavy water nuclear reactors. Methods of leakage detection are described and characteristics of different methods of detection and of differentiating between allowable and abnormal leakages are given.
The sensitivity of systems required to ensure early detection of developing leaks and to provide warning of possible leak-before-break situations is considered, and recommendations are given to reduce spurious alarms. The same requirements apply in the case of the break preclusion concept and other concepts for the assurance of the integrity of components and pipes.
Recommendations are given for data display that allows data to be presented in a clear and concise manner to enable operators to take appropriate actions to minimize the risk of hazard to plant equipment and to personnel. Requirements are given for recording and logging, as well as for the summation of individual signals for trend detection.
This document specifies requirements for leakage detection data, its logical arrangement and the display of information that enables the operator to take appropriate action. A secondary objective is to standardize the criteria, methods and procedures used to demonstrate the design and operational adequacy of the reactor coolant and associated systems (RCAS) leakage detection systems used in light water and heavy water nuclear reactors.