1 Scope
This European Standard specifies a method for determining the tensile and compressive
load capacity and load displacement characteristics of wall ties screwed, nailed,
grouted or otherwise attached to frame elements or to inner leaf materials. The test
is intended for ties for connecting masonry leaves to frame structures and to the
inner leaves of cavity walls other than by embedding the inner connection in a mortar
joint.