1 Scope
This PART of IEC 62805 specifies methods for measuring the transmittance and reflectance of glass used in
photovoltaic (PV) modules and provides instructions on how to calculate the effective
hemispherical transmittance and reflectance of this glass.
This document is applicable to PV glasses used in PV modules, including ultra-clear
patterned glass, anti-reflective coated (AR) glass, transparent conductive oxide coated
(TCO) glass and other kinds of PV glass used in PV modules.
These test methods are designed to provide reproducible data appropriate for comparison
of results among laboratories or at different times by the same laboratory and for
comparison of data obtained on different PV glasses.
These test methods have been found practical for glass having both specular and diffuse
optical properties.