Metallic communication cable test methods - Electromagnetic compatibility (EMC). Screening or coupling attenuation. Absorbing clamp method

Metallic communication cable test methods - Electromagnetic compatibility (EMC). Screening or coupling attenuation. Absorbing clamp method

Regular price
£306.00
Sale price
£306.00
Regular price
£153.00
Sold out
Unit price
per 

1   Scope

The absorbing clamp method is suitable to determine the screening- or the coupling-attenuation of metallic communication cables in the frequency range of 30 MHz to 1 000 MHz (2 400 MHz), depending on the performance of the clamp. It is an alternative method to the triaxial method of IEC 62153‑4‑4 or IEC 62153‑4‑9. Due to the undefined outer circuit of this absorbing clamp method, the test results obtained at different places and laboratories could vary by at least ± 6 dB.