1 Scope
This Part of IEC 62788 provides a method and guidelines for measuring the volume resistivity of materials
used as encapsulation, edge seals, front-sheets, backsheets, or any other insulating
material in a photovoltaic (PV) module. The test is performed on dry, humid or wet
preconditioned samples. In the case of frontsheets and backsheets comprised of multiple
layers, the measured resistivity is an effective value. This test is designed for
room temperature measurement, but can also be utilized at higher temperatures.
Degradation of PV modules is known to occur in Part by electrochemical corrosion,
and other potential induced degradation processes. These processes may be dependent
upon the resistivity of a polymeric component. Therefore, the DC resistivity of polymeric
components is relevant to module design and durability in the field. The resistivity
may depend on cure state, temperature, water content, and voltage history. A number
of options are included to allow the measurement to be performed in a manner consistent
with representative fielded module conditions.
Most resistivity measurement methods and equipment typically become inaccurate and
variable for materials with volume resistivity above 1016 Ω∙cm [5]1. Therefore, this standard is used for measurements less than 1·1017 Ω∙cm.
Both monolithic and multilayer materials (e.g. frontsheets and backsheets) are suitable
for measurement. Methods are described for room temperature measurement, with guidelines
included for testing at elevated temperatures.
Results will vary with moisture content, therefore materials should be tested in a
manner anticipatory of usage. Preconditioning procedures for dry, humid and wet environments
are included.
Depending on the material, voltage history will affect the measured result. The rate
of change of current, and time to equilibrium varies with material often taking hours
or days to come to a static level. For this reason, long and short duration methods
are included (Methods A and B). The specified short-duration alternating polarity
Method B is intended for qualitative comparison. Method A, long-duration on/off polarity,
is recommended for characterization with regard to PID resistance.
Measurements obtained using either method may be used by material manufacturers for
the purpose of quality control of their electrical insulating material as well as
for reporting in product datasheets. PV module manufacturers may use these methods
for the purpose of material acceptance, material selection, process development, design
analysis, or failure analysis.
This measurement method can also be utilized to monitor the performance of electrical
insulating materials after weathering, to assess their durability.