1 Scope
This International Standard specifies the minimum performance requirements, technical
characteristics and methods of testing, and required test results, for a bridge navigational
watch alarm system (BNWAS) as required by Chapter V of the International Convention
for the Safety of Life at Sea (SOLAS), as amended. It takes account of the general
requirements given in IMO resolution A.694(17) and is associated with IEC 60945. When a requirement in this International Standard is different from IEC 60945, the requirement in this standard takes precedence.
This standard incorporates the parts of the performance standards included in IMO
resolution MSC.128(75).
NOTE 1 All text of this standard, whose wording is identical to that of IMO resolution MSC.128(75), is printed in italics, and the resolution and associated performance standard paragraph numbers are indicated in brackets.
(128/A1) The purpose of a bridge navigational watch alarm system (BNWAS) is to monitor bridge
activity and detect operator disability which could lead to marine accidents. The
system monitors the awareness of the Officer of the Watch (OOW) and automatically
alerts the Master or another qualified OOW if for any reason the OOW becomes incapable
of performing the OOW's duties. This purpose is achieved by a series of indications
and alarms to alert first the OOW and, if he is not responding, then to alert the
Master or another qualified OOW. Additionally, the BNWAS may provide the OOW with
a means of calling for immediate assistance, if required. The BNWAS should be operational
whenever the ship is underway at sea (SOLAS V/19.2.2.3).
NOTE 2 BNWAS may not, in practice, be realised as a stand alone equipment. It may be integrated in other equipment such as radar, ECDIS, etc.