3.1 Scope
This part of IEC 60598 specifies requirements for
-
– luminaires for road, street lighting and other public outdoor lighting applications;
-
– tunnel lighting;
-
– column-integrated luminaires with a minimum total height above normal ground level of 2,5 m;
and for use with electrical lighting sources on supply voltages not exceeding 1 000 V.
NOTE Column integrated luminaires with a total height below 2,5 m are under consideration.
3.1.1 Normative references
The normative references listed in Section 0 of IEC 60598‑1 apply to this part as well as the following reference:
- IEC 60364‑7‑714, 1996, Electrical installations of buildings – Part 7: Requirements for special installations or locations – Section 714: External lighting installations
- IEC 60068‑3‑76:1997, Environmental testing – Part 2-75: Tests – Test Eh: Hammer tests
- IEC 62262: 2002, Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)