HVDC Grid Systems and connected Converter Stations. Guideline and Parameter Lists for Functional Specifications - Guidelines

HVDC Grid Systems and connected Converter Stations. Guideline and Parameter Lists for Functional Specifications - Guidelines

Regular price
£348.00
Sale price
£348.00
Regular price
£174.00
Sold out
Unit price
per 

What is PD CLC/TS 50654‑1 about?  

PD CLC/TS 50654‑1 is the first part of the PD CLC/TS 50654 series of documents on HVDC grid systems and connected converter stations. PD CLC/TS 50654‑1 is an international standard on HVDC grid systems and connected converter stations that aim to improve the efficiency of transmitting enormous amounts of electricity over long distances. 

PD CLC/TS 50654‑1 describe specific functional requirements for HVDC Grid Systems. The terminology “HVDC Grid Systems” is used here describing HVDC systems for power transmission having more than two converter stations connected to a common DC circuit. 

PD CLC/TS 50654‑1 is applicable to high voltage systems, i.e., having typically nominal DC voltages higher than 50 kV with respect to earth are considered in PD CLC/TS 50654‑1. 

Note: While the physical principles of DC networks are voltage-independent, the technical options for designing equipment get much wider with lower DC voltage levels, e.g., in the case of converters or switchgear. 

Who is PD CLC/TS 50654‑1 for? 

PD CLC/TS 50654‑1 on HVDC grid systems and connected converter stations is useful for: 

  • HVDC grid systems manufacturers 
  • HVDC grid systems designers 
  • Entities involved in the installation of HVDC grid systems 
  • Testing laboratories/ test providers for HVDC grid systems 

Why should you use PD CLC/TS 50654‑1?  

HVDC Grid Systems are a new field of technology. There are very few systems with a small number of converter stations in operation, some more are in execution or in detailed planning. 

PD CLC/TS 50654‑1 provides you with guidelines for functional specification of HVDC grid systems and connected converter stations. 

The guidelines, characteristics, installation requirements provided by PD CLC/TS 50654‑1 helps you to improve the efficiency of HVDC power transmissions between convertor stations and to expand the energy networks. 

What is changed since the last update?  

PD CLC/TS 50654‑1:2020 supersedes CLC/TS 50654-1:2018. PD CLC/TS 50654‑1:2020 has some technical changes. These include: 

  • New content concerning AC/DC converter stations 
  • New content concerning HVDC Grid System installations, including DC switching stations 
  • New content concerning HVDC Grid System integration tests