Geotechnical investigation and testing. Geohydraulic testing - Pumping tests

Geotechnical investigation and testing. Geohydraulic testing - Pumping tests

Regular price
£272.00
Sale price
£272.00
Regular price
£136.00
Sold out
Unit price
per 

What is ISO 22282-4-Pumping tests for geotechnical investigation about?  

ISO 22282-4 is the fourth part of a multi-series of documents that is applicable to geotechnical investigation and testing on geohydraulic testing. 

ISO 22282-4 establishes requirements for pumping tests as part of geotechnical investigation service in accordance with EN 19971 and EN 19972. 

ISO 22282-4 applies to pumping tests performed on aquifers whose permeability is such that pumping from a well can create a lowering of the piezometric head within hours or days depending on the ground conditions and the purpose.    

The tests concerned by ISO 22282-4 are those intended for evaluating the hydrodynamic parameters of an aquifer and well parameters such as: 

  • Permeability of the aquifer 
  • Radius of influence of the pumping 
  • Pumping rate of a well 
  • Response of drawdown in an aquifer during pumping 
  • Skin effect 
  • Well storage, 
  • Response of recovery in an aquifer after pumping 

Note: It covers pumping tests carried out in soils and rock 

Who is ISO 22282-4- Pumping tests for geotechnical investigation for? 

ISO 22282-4 on geohydraulic pumping tests is useful for:   

  • Hydrogeologists  
  • Civil engineers     
  • Geotechnical engineers 
  • Technical consultants  
  • Contractors 

Why should you use ISO 22282-4- Pumping tests for geotechnical investigation? 

Geotechnical testing is carried out by geotechnical engineers, geotechnical technicians, or engineering geologists to determine the features of a worksite, such as the physical attributes. Geotechnical studies are conducted to assess the geology, seismologic, and soil conditions that affect the project's safety, cost-effectiveness, design, and execution. 

The test described under ISO 22282-4 is to determine and access rules and regulations on geotechnical testing services. The test entails measuring the pumped discharge as well as the water level in the test well and piezometers as a function of time before, during, and after pumping. Pumping from a well to lower the piezometric surface of the groundwater. 

Pumping tests as part of geotechnical investigation and testing when governed by ISO 22282-4, can assist you in making better decisions about the project's safety, cost-effectiveness, design, and implementation.   

You can view the latest version of this standard here.