1 Scope
This part of IEC 61935, which is a blank detail specification, describes work area cord with M12 4 poles
d-code connectors, as used in the ISO/IEC 24702 and IEC 61918.
According to the above cabling specifications, although these cords have only two
pairs, their transmission performances, when applicable, are at least category 5 compliant
for which the requirements are given in ISO/IEC 11801:2002/AMD2:2010, Clause 13.
This specification should be used in conjunction with IEC 61156‑1, IEC 61156‑6 and IEC 61076‑2‑101 type D. The blank detail specification determines the layout and style for detail
specifications describing cords with transmission characteristics up to 100 MHz for
digital communications. Detail specifications, based on the blank detail specification,
may be prepared by a national organization, a manufacturer, or a user.
Test configuration applicable to cords is detailed in IEC 61935‑2.