1 Scope
NOTE 1 If the pressure regulating system of a VIPR is acting as the primary valve operating mechanism, it is covered by the relevant closure standard, e.g. ISO 10297, ISO 17871, ISO 17879 and ISO 23826. This also includes designs where closure of the primary valve operating mechanism of a VIPR is obtained by closing the seat of the pressure regulating system.
NOTE 2 If the primary valve operating mechanism of a VIPR is located at the low-pressure side of the pressure regulating system, it is covered by the relevant closure standard, e.g. ISO 10297, ISO 17871, ISO 17879 and ISO 23826.
NOTE 3 The term “pressure receptacle” is used within this document to cover instances where no differentiation is necessary between gas cylinders, bundles of cylinders, pressure drums and tubes.
-
a) medical applications (see ISO 10524‑3);
-
b) liquefied petroleum gas (LPG);
-
c) cryogenic applications.
NOTE 4 Additional requirements for a VIPR with a residual pressure device (RPD) are specified in ISO 15996.
NOTE 5 Additional requirements for pressure relief valves can exist in international/regional regulations/ standards.