1 Scope
This part of IEC 60079 is applicable to equipment protected by enclosure and surface temperature limitation
for use in explosive dust atmospheres. It specifies requirements for design, construction
and testing of Ex Equipment and Ex Components.
This document supplements and modifies the general requirements of IEC 60079‑0. Where a requirement of this document conflicts with a requirement of IEC 60079‑0, the requirement of this document takes precedence.
This document does not apply to dusts of explosives, which do not require atmospheric
oxygen for combustion, or to pyrophoric substances.
This document does not apply to Ex Equipment or Ex Components intended for use in
underground parts of mines as well as those parts of surface installations of such
mines endangered by firedamp and/or combustible dust.
This document does not take account of any hazard due to an emission of flammable
or toxic gas from the dust.
This document does not contain requirements for Ex Equipment used in areas where both
combustible dust and explosive gas atmospheres can occur, whether simultaneously or
separately. Requirements for explosive gas atmospheres can be found in other parts
of the IEC 60079 series. Guidance on Ex Equipment to be used where combustible dust and explosive gas atmospheres
occur simultaneously ("hybrid mixtures") can be found in IEC 60079‑14.
Where the Ex Equipment has to meet other environmental conditions, for example, protection
against ingress of water and resistance to corrosion, additional measures which do
not adversely affect the integrity of the enclosure can be necessary.