1 Scope
This document describes an objective stroboscopic effect visibility (SVM) meter, which can be applied for performance testing of lighting
equipment under different operational conditions.
The stroboscopic effects considered in this document are limited to the objective assessment by a human observer
of visible stroboscopic effects of temporal light modulation of lighting equipment in general indoor applications,
with typical indoor light levels (> 100 lx) and with moderate movements of an observer
or nearby handled object (< 4 m/s). Details on restriction of the applicability of
the stroboscopic effect visibility measure is given in Clause A.1.
For assessing unwanted stroboscopic effects in other applications, such as the misperception of rapidly rotating or moving machinery
in an industrial environment for example, other metrics and methods can be required.
The object of this document is to establish a common and objective reference for evaluating
the performance of lighting equipment in terms of stroboscopic effect. Temporal changes in the colour of the light (chromatic effects) are not considered
in this test. This document describes the methodology for SVM and does not define
any limits.
The objective method and procedure described in this document are based on CIETN 006:2016 on
temporal light artefacts (TLAs).
The method described in this document can be applied to objectively assess the stroboscopic effect of lighting equipment that is powered from any type of source, AC mains, DC mains,
battery fed or fed through an external dimmer.