1 Scope
This part of IEC 60068 is applicable to all electrical and electronic components whose terminations or integral
mounting devices are liable to be submitted to stresses during normal assembly or
handling operations.
Table 1 provides details of the applicable tests.
Table 1
—
Application
| Test | Type | Component | Mounted/not mounted |
|---|---|---|---|
| Ua1 | Tensile | Leaded devices | Not mounted |
| Ua2 | Thrust | Leaded devices | Not mounted |
| Ub | Bending | Leaded devices | Not mounted |
| Uc | Torsion | Leaded devices | Not mounted |
| Ud | Torque | Threaded stud or screw termination | Not mounted |
| Ue1 | Bending | Surface mounted devices | Mounted |
| Ue2 | Pull/push | Surface mounted devices | Mounted |
| Ue3 | Shear | Surface mounted devices | Mounted |