BS EN 61000-4-6:2009 Electromagnetic compatibility (EMC). Testing and measurement techniques. Immunity to conducted disturbances, induced by radio-frequency fields
BS EN 61000-4-6 relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 9 kHz up to 80 MHz. Equipment not having at least one conducting cable (such as mains supply, signal line or earth connection) which can couple the equipment to the disturbing RF fields is excluded.
BS EN 61000-4-6 defines test methods for measuring the effect that conducted disturbing signals, induced by electromagnetic radiation, have on the equipment concerned. The simulation and measurement of these conducted disturbances are not adequately exact for the quantitative determination of effects. The test methods defined are structured for the primary objective of establishing adequate repeatability of results at various facilities for quantitative analysis of effects.
BS EN 61000-4-6 establishes a common reference for evaluating the functional immunity of electrical and electronic equipment when subjected to conducted disturbances induced by radio-frequency fields. The test method documented in BS EN 61000-4-6 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon.
Contents of BS EN 61000-4-6:
- Introduction
- Scope and object
- Normative references
- Terms and definitions
- General
- Test levels
- Test equipment
- Test generator
- Coupling and decoupling devices
- Coupling/decoupling networks (CDNs)
- Clamp injection devices
- Direct injection devices
- Decoupling networks
- Verification of the common mode impedance at the EUT port of coupling and decoupling
- devices
- Insertion loss of the 150 Ω to 50 Ω adapters
- Setting of the test generator
- Setting of the output level at the EUT port of the coupling device
- Test set-up for table-top and floor-standing equipment
- Rules for selecting injection methods and test points
- Injection method
- Ports to be tested
- Procedure for CDN injection application
- Procedure for clamp injection when the common-mode impedance requirements can be met
- Procedure for clamp injection when the common-mode impedance requirements cannot be met
- Procedure for direct injection
- EUT comprising a single unit
- EUT comprising several units
- Test procedure
- Evaluation of the test results
- Test report