1   Scope and object

This part of IEC 60512 provides a listing of the 60512 series of standards for specific tests that are created for connectors. Further it gives cross-references with the former (60)512 standards, where different test numbers were used. The connector tests as such are mainly identical with the previously published standards; minor changes may be introduced due to technical developments (e.g. other soldering temperatures in soldering tests, resulting from the introduction of lead-free soldering). The former issues were in booklets, with several related tests in one document, while the present issues are leaflets, each featuring one single test.
Test No. Test name Applicable part  of IEC 60512 Former IEC (60)512 part, test number
- General -1 512-1
  Applicable publications -1-100 none
       
  Part 1: General examination    
1a Visual examination -1-1 -2 test 1a
1b Examination of dimension and mass -1-2 -2 test 1b
1c Electrical engagement length -1-3 -2 test 1c
1d (With corrigendum) Contact protection effectiveness (scoop-proof) -1-4 none
       
  Part 2: Electrical continuity and contact resistance tests    
2a Contact resistance - Millivolt level method -2-1 -2 test 2a
2b Contact resistance - Specified test current method -2-2 -2 test 2b
2c Contact resistance variation -2-3 -2 test 2c
2d (Vacant)    
2e Contact disturbance -2-5 -2 test 2e
2f Housing (shell) electrical continuity -2-6 -2 test 2f
2g (Vacant)    
       
  Part 3: Insulation tests    
3a Insulation resistance -3-1 -2 test 3a
       
  Part 4: Voltage stress tests    
4a Voltage proof -4-1 -2 test 4a
4b Partial discharge -4-2 -2 test 4b
4c Voltage proof of pre-insulated crimp barrels -4-3 -2 test 4c
       
  Part 5: Current-carrying capacity tests    
5a Temperature rise -5-1 -3 test 5a
5b Current-temperature derating -5-2 -3 test 5b
       
  Part 6: Dynamic stress tests    
6a Acceleration, steady state -6-1 -4 test 6a
6b Bump -6-2 -4 test 6b
6c Shock -6-3 -4 test 6c
6d Vibration (sinusoidal) -6-4 -4 test 6d
6e Random vibration -6-5 none
       
  Part 7: Impact tests (free components)    
7a Free fall (repeated) -7-1 -5 test 7a
7b Mechanical strength impact -7-2* -5 test 7b
       
  Part 8: Static load tests (fixed components)    
8a Static load, transverse -8-1 -5 test 8a
8b Static load, axial -8-2 -5 test 8b
8c Robustness of actuating lever -8-3 -5 test 8c
       
  Part 9: Endurance tests    
9a Mechanical operation -9-1 -5 test 9a
9b Electrical load and temperature -9-2* -5 test 9b
9c Mechanical operation (engaging and separating) with electrical load -9-3 -5 test 9c
9d Durability of contact retention system and seals (maintenance, ageing) -9-4 -5 test 9d
9e Current loading, cyclic -9-5 -5 test 9e
       
  Part 10: Overload tests    
10a withdrawn    
10b withdrawn    
10c (Vacant)    
10d Electrical overload (connectors) -10-4 Ed.2. -5 test 10d
       
  Part 11: Climatic tests    
11a Climatic sequence -11-1 -6 test 11a
11b Combined/sequential cold, low air pressure and damp heat -11-2 -6 test 11b
11c Damp heat, steady state -11-3 -6 test 11c
11d Rapid change of temperature -11-4 -6 test 11d
11e Mould growth -11-5 -6 test 11e
11f Corrosion, salt mist -11-6 -6 test 11f
11g Flowing mixed gas corrosion test -11-7 Ed.2. none
11h Sand and dust -11-8 none
11i Dry heat -11-9 -6 test 11i
11j Cold -11-10 -6 test 11j
11k Low air pressure -11-11 -6 test 11k
11l (Not to be used)    
11m Damp heat, cyclic -11-12 -6 test 11m
11n Gas tightness, solderless wrapped connections -11-13 -6 test 11n
11o (Not to be used)    
11p Flowing single gas corrosion test -11-14 Ed.2. none
       
  Part 12: Soldering tests    
12a Solderability, wetting, solder bath method -12-1 -6 test 12a
12b Solderability, wetting, soldering iron method -12-2 -6 test 12b
12c Solderability, de-wetting -12-3 -6 test 12c
12d Resistance to soldering heat, solder bath method -12-4 -6 test 12d
12e Resistance to soldering heat, soldering iron method -12-5 -6 test 12e
12f Sealing against flux and cleaning solvents in machine soldering -12-6 none
12g Solderability, wetting balance method -12-7 none
       
  Part 13: Mechanical operating tests    
13a Engaging and separating forces -13-1 Ed.2 -7 test 13a
13b Insertion and withdrawal forces -13-2 -7 test 13b
13c withdrawn   -7 test 13c
13d withdrawn   -7 test 13d
13e Polarizing and keying method 13-5 -7 test 13e
       
  Part 14: Sealing tests    
14a (Vacant)    
14b Sealing -Fine air leakage -14-2 -7 test 14b
14c (Vacant)    
14d Immersion- Waterproof -14-4 -7 test 14d
14e Immersion at low air pressure -14–5 -7 test 14e
14f Interfacial sealing -14-6 -7 test 14f
14g Impacting water -14-7 none
       
  Part 15: Connector tests (mechanical)    
15a Contact retention in insert -15-1 -8 test 15a
15b Insert retention in housing (axial) -15-2 -8 test 15b
15c Insert retention in housing (torsional) -15-3 -8 test 15c
15d Contact insertion, release and extraction force -15-4 -8 test 15d
15e Contact retention in insert, cable nutation -15-5 -8 test 15e
15f Effectiveness of connector coupling devices -15-6 -8 test 15f
15g Robustness of protective cover attachment -15-7 -8 test 15g
15h Contact retention system resistance to tool application -15-8 none
       
  Part 16: Mechanical tests on contacts and terminations    
16a Probe damage -16-1 -8 test 16a
16b Restricted entry -16-2 -8 test 16b
16c Contact-bending strength -16-3 -8 test 16c
16d Tensile strength (crimped connections) -16-4 -8 test 16d
16e Gauge retention force (resilient contacts) -16-5 -8 test 16e
16f Robustness of terminations -16-6 -8 test 16f
16g Measurement of contact deformation after crimping -16-7 -8 test 16g
16h Insulation grip effectiveness (crimped connections) -16-8 -8 test 16h
16i Grounding contact spring holding force -16-9 -8 test 16i
16j (Vacant)    
16k Stripping force, solderless wrapped connections -16-11 -8 test 16k
16m Un-wrapping, solderless wrapped connections -16-13 -8 test 16m
16n Bending strength, fixed male tabs -16-14 -8 test 16n
16o (Not to be used)    
16p Torsional strength, fixed male tabs -16-16 -8 test 16p
16q Tensile and compressive strength, fixed male tabs -16-17 -8 test 16q
16r Deflection of contacts, simulation -16-18 -8 test 16r
16s (Vacant)    
16t Mechanical strength (wired terminations of solderless connections) -16-20 none
16u Whisker test via the application of external mechanical stresses -16-21 none
       
  Part 17: Cable clamping tests    
17a Cable clamp robustness -17-1 -9 test 17a
17b Cable clamp resistance to cable rotation -17-2 -9 test 17b
17c Cable clamp resistance to cable pull (tensile) -17-3 -9 test 17c
17d Cable clamp resistance to cable torsion -17-4 -9 test 17d
       
  Part 18: Explosion hazard tests    
       
  Part 19: Chemical resistance tests    
19a Fluid resistance of pre-insulated crimp barrels -19-1 -9 test 19a
19b (Vacant)    
19c Fluid resistance -19-3 none
       
  Part 20: Fire hazard tests    
20a Flammability, needle-flame -20-1 -9 test 20a
20b Flammability tests - fireproofness -20-2 none
20c Flammability, glow-wire -20-3 -9 test 20c
       
  Part 21: R.F. resistance tests    
21a R.F. shunt resistance -21-1 -9 test 21a
       
  Part 22: Capacitance tests    
22a Capacitance -22-1 -9 test 22a
       
  Part 23: Screening and filtering tests    
23a (Vacant)    
23b Suppression characteristics of integral filters -23-2 -9 test 23b
23c Shielding effectiveness of connectors and accessories -23-3 none
23c Corrigendum 1 to IEC 60512-23-3 -23-3 none
23d Transmission line reflections in the time domain -23-4 none
23e (vacant)    
23f (vacant)    
23g Effective transfer impedance of connectors -23-7 none
       
  Part 24: Magnetic interference tests    
24a Residual magnetism -24-1 -9 test 24a
       
  Part 25: Signal integrity tests    
25a Crosstalk ratio -25-1 none
25b Attenuation (insertion loss) -25-2 none
25c Rise time degradation -25-3 none
25d Propagation delay -25-4 none
25e Return loss -25-5 none
25f Eye pattern and jitter -25-6 none
25g Impedance, reflection coefficient, and voltage standing wave ratio (VSWR) -25-7 none
25h Balance of symmetrical signals -25-8* none
25i Signal integrity tests - Alien crosstalk -25-9 none
26-100 Measurement setup, test and reference arrangements and measurements for connectors according to IEC 60603‑7 – Tests 26a to 26g** -26-100 none
27a/g** Signal integrity tests up to 500 MHz -27-1 to 27-7* none
27-100 Signal integrity tests up to 500 MHz on IEC 60603‑7 series connectors – Tests 27a to 27g** -27-100* none
28-100 Signal integrity tests up to 1000 MHz on 60603-7 and 61076-3 series connectors – Tests 28a to 28g** -28-100* none
29-100
Signal integrity tests up to 500 MHz on M12 style connectors - Tests 29a to 29g**
-29-100* none
99-001 Connectors used in twisted pair communication cabling with remote power -99-001* none
*  In preparation.
**  For IEC 60512‑26‑100 to IEC 60512‑29‑100, the letters ‘a’ to ‘g’ indicate the following tests:
a - Insertion loss
b - Return loss
c - Near-end crosstalk (NEXT)
d - Far-end crosstalk (FEXT),
e - Transfer impedance (Zt)
f - Transverse conversion loss (TCL)
g - Transverse conversion transfer loss (TCTL)