1 Scope
This International Standard specifies test methods to determine the following characteristics of the composition cork intended to be used as a joint filler of expansion joints of concrete or other construction materials:
-
— apparent density,
-
— expansion in water,
-
— compression,
-
— recovery,
-
— extrusion,
-
— water absorption.
These test methods apply to agglomerated cork joint filler with a nominal thickness ranging from 6,3 mm to 25 mm.