What is BS EN 62562- Cavity resonator method about? 

BS EN 62562 is an international standard that focuses on the techniques to measure the complex permittivity of low-loss dielectric plates. 

BS EN 62562 describes a measurement method of dielectric properties in the planar direction of the dielectric plate at microwave frequency. The method described in BS EN 62562 is called a cavity resonator method.  

BS EN 62562 has been created to develop new materials and to design microwave active and passive devices for which standardization of measurement methods of material properties is increasingly important.  

BS EN 62562 is applicable for the measurements on the following condition: 

  • Frequency: 2 GHz < f < 40 GHz 
  • Relative permittivity: 2 < ε ' < 100 
  • Loss tangent: 10–6 < tanδ < 10-2 

Who is BS EN 62562- Cavity resonator method for 

BS EN 62562 on cavity resonator method to measure the complex permittivity of low-loss dielectric plates is relevant to: 

  • Electrical engineers 
  • Electricians 
  • Testing authorities 
  • Manufacturers of measuring equipment and apparatus 

Why should you use BS EN 62562- Cavity resonator method? 

The cavity resonator method is used for measuring the loss tangent and dielectric constants for dielectric plates with the help of resonant frequencies. 

BS EN 62562 lays down the technicalities for carrying out a methodology to measure the complex permittivity of low-loss dielectric plates. BS EN 62562 gives you detailed information about the equipment and apparatus needed to perform the test, explains the measurement parameters, and helps users with theory and calculations.  

BS EN 62562 presents a measurement procedure along with a suitable example of measured results and accuracy. BS EN 62562 gives a method that proves to be a very beneficial method as it helps the users to: 

  • Measure the relative permittivity ε ' and loss tangent tanδ values of a dielectric plate sample, accurately and non-destructively 
  • Temperature dependence of complex permittivity  
  • The measurement accuracy is within 0.3 percent for ε ' and within 5×10–6 for tanδ  