What is BS EN 62129-1- Optical spectrum analyzers about? 

BS EN 62129-1 is a safety standard on the calibration of wavelength/optical frequency measurement instruments. 

BS EN 62129-1 specifies procedures for calibrating an optical spectrum analyzer that is developed for use in fibre-optic communications and designed to measure the power distribution of an optical spectrum. 

BS EN 62129-1 describes a set of operations that establish, under specified conditions, the relationship between the values of quantities indicated by a measuring instrument and the corresponding values realized by standards. 

Note: BS EN 62129-1 does not apply to an optical wavelength meter that measures only centre wavelengths, a Fabry-Perot interferometer or a monochromator that has no display unit. 

Who is BS EN 62129-1- Optical spectrum analyzers for?  

BS EN 62129-1 on the calibration of wavelength/optical frequency measurement instruments is relevant to: 

  • Manufacturers of optical spectrum analyzers 
  • Testing authorities 

Why should you use BS EN 62129-1- Optical spectrum analyzers? 

An optical spectrum analyzer is an optical instrument for measuring the power distribution of a spectrum with respect to wavelength (frequency). 

BS EN 62129-1 assist with the power level indicated by an optical spectrum analyzer undergoing calibration at a specified wavelength resolution setting. BS EN 62129-1 discusses the reference conditions of influencing parameters, their nominal values, and their tolerance bands, with respect to which the uncertainty at reference conditions is specified. BS EN 62129-1 provides guidance on the wavelength deviation and calibration. 

Overall, BS EN 62129-1 is useful as it guides on the calibration of wavelength/optical frequency measurement instrument of the optical spectrum analyzers which can be helpful for your business. 

What’s changed since the last update? 

BS EN 62129-1:2016 supersedes BS EN 62129:2006 which is withdrawn. 

BS EN 62129-1:2016 replaces the first edition of IEC 62129, published in 2006. BS EN 62129-1:2016 constitutes a technical revision. 

BS EN 62129-1:2016 includes the following significant technical changes with respect to the previous edition: 

  • Update of terms and definitions 
  • Update of calibration conditions 
  • Calculation changes of uncertainties related to wavelength temperature dependence, power linearity, power level temperature dependence 
  • Move of Annex E to the bibliography