1 Scope
This European Technical Report provides guidance on assessing the possibility of inadvertent
extraction of energy from an electromagnetic field propagated from radio frequency
(RF), radar or other transmitter antennas and the coupling of this energy to an electro-explosive
device (EED) in a manner capable of causing initiation. The frequency range covered
by this European Technical Report is 9 kHz to 60 GHz. This European Technical Report
only applies to bridge-wire devices which are directly initiated by radio frequency
current and does not apply to special detonators, for example, electronic detonators.
It does not cover the similar hazard arising from electromagnetic fields generated by other means, for example electric
storms, electricity generating plant or power transmission lines.
This European Technical Report does not apply to the following equipment:
-
– air bag igniters for automotive applications (including the igniters before they are fitted);
-
– special pyrotechnic devices;
-
– pyromechanisms;
-
– igniters for fireworks;
-
– special military devices;
-
– special safety equipment.
NOTE The methods of assessment from 9 GHz to 60 GHz are based on extrapolation of data for frequencies below 9 GHz.