Animal feeding stuffs. Determination of selenium by hydride generation atomic absorption spectrometry (HGAAS) after microwave digestion (digestion with 65 % nitric acid and 30 % hydrogen peroxide)

Animal feeding stuffs. Determination of selenium by hydride generation atomic absorption spectrometry (HGAAS) after microwave digestion (digestion with 65 % nitric acid and 30 % hydrogen peroxide)

Regular price
£166.00
Sale price
£166.00
Regular price
£83.00
Sold out
Unit price
per 

1   Scope

This European Standard specifies a method for the determination of selenium in animal feeding stuffs by hydride generation atomic absorption spectrometry (HGAAS) after microwave pressure digestion.
The method was successfully tested by an inter-laboratory study of CEN/TC 327/WG 4 in the range of 0,25 mg/kg to 74 mg/kg.
The limit of quantification is 0,5 µg/l of the test solution which corresponds to the calibration standard 2. Using a test portion of 0,5 g and a volume of the test solution of 25 ml after pressure digestion the limit of quantification is calculated as 0,125 mg/kg in the feed material.

NOTE A lower limit of quantification could be achieved – each laboratory has to prove it.