1 Scope
This document specifies an inductively coupled plasma optical emission spectrometric
method for the determination of the chromium content (mass fraction) between 5,0 %
(m/m) and 27,0 % (m/m) in alloyed steels.
The method doesn't apply to alloyed steels having carbon contents higher than 1 % and