1 Scope
-
a) in those cargo compartments of civil transport aircraft where they constitute one means of complying with applicable airworthiness regulations;
-
b) on a voluntary basis, when deemed appropriate by operators to improve fire protection in aircraft cargo compartments where airworthiness regulations do not currently mandate their use.
-
a) Class B aircraft cargo compartments according to CS-25, CCAR-25, JAS Part 3 or 14CFR Part 25 25.857 (b), in accordance a) or b) above;
-
b) Class E aircraft cargo compartments according to CS-25, CCAR-25, JAS Part 3 or 14CFR Part 25 25.857 (e), in accordance with b) above;
-
c) Class F aircraft cargo compartments according to CS-25 § 25.857(f ) and AMC to CS-25.855 and 25.857, or 14CFR Part 25 § 25.857(f ) and FAA Advisory Circular AC25.857-X, in accordance with a) above.
NOTE 1 Though nothing formally prevents a fire resistant container (FRC) from being carried in a lower deck Class C aircraft cargo compartment, it is not intended for this use since its fire containment capability would be redundant with that of the aircraft’s fire detection and suppression system, which it could hamper. Consult current regulatory guidance materials and aircraft type’s Weight and Balance Manual whenever available.
NOTE 2 See Clause 2 and 4.1 and 4.2 for applicable containers airworthiness approval and general design standards.
NOTE 3 Nothing, however, prevents additional use of self-contained fire detection or suppression devices within fire resistant containers (FRCs), but such devices are not specified herein (see 4.5.5).