1 Scope
This document specifies the minimum design and performance criteria and testing methods
of passive fire-resistant containers (FRCs) used in cargo compartments of civil transport aircraft to improve fire protection.
This document does not cover requirements for fire detection or suppression devices.
The specified fire-resistant containers (FRCs) are passive devices capable of containing a fire for a specific duration.